IKEUCHI USA, Inc. The Fog Engineers

COOLJetter® CLJ-CSA

Spray capacity 14.2 L/hr Mean droplet diameter 10–30 μm (*1) Power consumption 210 W (50 Hz), 250 W (60 Hz) (*2)
Water pressure 6.0 MPa Air pressure - Air consumption -

Features

• This energy-efficient cooling unit produces Semi-Dry Fog® (*1) which is dispersed over a larger area using a fan (fog fan/ mist fan).
• It reduces temperatures by 3–5℃ with evaporative cooling of fog.
• Pump and water tank inclusive type (mobile cart type) that doesn't require a fixed installation space.
• This cooling fan unit is useful for prevention of heatstroke, dust dispersion, etc.
• Spray volume is 14.2 L/hr (at 6 MPa), making it suitable for use in small spaces.

*1) We define Semi-Dry Fog® as a fog with a mean droplet diameter (mean fog droplet size) of 10–30 μm.
Because this fine fog does not include large droplets which can result in wetting, it provides superb performance quality for human users.
"Dry mist," despite its similar name, has no specified droplet diameter as part of its definition. Dry mist droplet sizes vary significantly by producer and product.

*2) Power supply: 100 VAC (50 Hz/ 60 Hz)

Note: CLJ-CSA is the successor to the model CLJ-CSA-F.

Applications

Outdoor cooling: Cooling directly toward people, heatstroke prevention, heat reduction for heat-extreme working environments
Humidification: Dust suppression, preventing dryness, health care

[Production / Processing Factory]
• Protecting workers from heatstroke, preventing dryness

[Waste Processing and Recycling Centers]
• Preventing dust dispersion inside buildings, protecting workers from heatstroke, health care

[Gymnasiums, Martial Arts Dojos, Soccer Fields, Tennis Courts, Athletic Fields/Facilities]
• Preventing heatstroke among athletes, preventing declines in practice/drill efficiency due to high temperatures

[Railway Yards]
• High temperature countermeasure during inspections and maintenance operations, preventing heatstroke among workers, boosting work efficiency and maintenance quality

[Wholesale Markets and Meat Processing Facilities]
• Cooling of facility staff/visitors, reducing stress among industrial-use livestock

Industries in which this product is used

Steelmaking, Pollution control, Machinery, Paper & Pulp, Printing, Food products, Agriculture, Livestock, Automotive manufacturing, Environment and Entertainment, Schools, Sports facilities

Product specifications

Mass
Model No. Mass (kg)
CLJ-CSA 44 (empty water tank)

 

Outer dimensions
Model No. Fan diameter (mm) Wide x Depth x Height (mm)
CLJ-CSA 450 575×1,020×1,320–1,400

 

Others
Model No.
Number of
nozzles (pcs.)
Spray capacity (L/hr)
Air flow (㎥/min)
(50/60 Hz)
Rated
supply voltage
Power consumption (W)
(50/60 Hz)
Accessories and Features
at 6 MPa
CLJ-CSA 6 14.2

165 (50 Hz)

186 (60 Hz)

100 VAC

210 (50 Hz)

250 (60 Hz)
• Pump
• 50L water tank (Full tank allows about 3 hours of spraying)
• Includes wheels
• Fan speed control (3 levels)
• 75-degree oscillation
• Low water level sensor (stops spray automatically before tank is empty)
• Direct tap water connection possible (optional parts required)
• Time integrator
• Intermittent timed ON/OFF control

 

Related products

[Discontinued] COOLJetter® CLJ-S-E
***************************************************************************************************…

Large-space Cooling and Humidification System LYOHM System
• Hydraulic cooling system producing Semi-Dry Fog®. (*1)• It reduces temperatures by 3–5℃ with evap…

How to order

Have a question? We don’ t provide cataloge items. We can provide custom-made products to meet your requirements.

Please inquire or order for a specific nozzle using our coding system.
The coding system is described in our catalog downloadable by clicking "Catalog" button placed below.
You can also contact us for further information to find suitable products.